					The difference between humidification and dehumidification in humidification and dehumidification
1  Constant temperature and humidity test chamber in order to realize the testing  conditions, inevitably of humidification and dehumidification of the box  operation, here various approaches are currently widely used in test box with  constant temperature and humidity in the analysis, pointed out their respective  advantages and disadvantages and recommended conditions.
2 Many methods of  constant temperature and humidity test chamber humidity representation,  experimental apparatus, usually with the conceptual description of humidity  relative humidity. The definition of relative humidity refers to the saturation  vapor pressure of water vapor in the air pressure and the water temperature of  the ratio is expressed as a percentage. By the water vapor saturation pressure  nature knowable, saturated vapour pressure is a function of temperature, and  water vapor may be independent of the air pressure, the people through a lot of  experiments and finishing to seek to express the relationship between the water  vapor saturation pressure and temperature, which has been shall be of the  formula of gove project and stoichiometric amounts used. It is currently the  meteorological departments humidity tables used.
3 Process test box with  constant temperature and humidity humidifier is actually improving the water  vapor pressure, initial humidification mode is to test the tank wall by spraying  water, control the temperature of the water so that the water surface saturation  pressure control. The wall of the box surface water to form larger surface, in  the face through the spread box to box to join the vapor pressure to make the  test box with constant temperature and humidity relative humidity increases,  this method appeared in the fifty's of the last century. Because at that time  the control of humidity is mainly simple adjustment by a mercury switch quantity  electric contact type conductivity meter, poor adaptability for control of hot  water tank of large lag and temperature control, so the transition process is  longer, can not meet the needs of alternating hot and humid demands more on  humidifying quantity, more important is in the tank wall spray inevitably, drops  drench the formation of different levels of pollution in the sample on the  sample. At the same time also has certain requirements on the  drainage.
4 This method will soon be steam humidification and  humidification of shallow dish replaced. But this method still has some  advantages. Although the control transition process longer test box with  constant temperature and humidity, but the stability of the system after the  humidity fluctuation is smaller, more suitable for damp heat test. In addition  to the humidification process steam is superheated does not increase the system  of extra heat. Also, when the control spray water temperature which is lower  than the temperature of test point requirements, spray water with dehumidifying  function.
5 With the development of damp heat test by test box with  constant temperature and humidity to alternating hot and humid, require  humidification and quick response, spray humidification can not meet the  requirements, the steam humidification and humidification of shallow dish method  to be used and developed to start.